PolyProPylene Blower / Fans
NEW DURA-FAN Blowers
DURA-FAN Series 160 |
|||||||
Dura-Fan 160 3P4P |
0.5HP / 0.37 KW |
3 Phase |
4 Pole |
1400 RPM |
50 Hz |
460 CMH |
270 CFM |
Dura-Fan 160-3P2P |
1.0HP / 0.75 KW |
3 Phase |
2 Pole |
2800 RPM |
50 Hz |
720 CMH |
420 CFM |
Dura-Fan 160-1P2P |
1.0HP / 0.75 KW |
1 Phase |
2 Pole |
2800 RPM |
50 Hz |
720 CMH |
420 CFM |
DURA-FAN SERIES 200 |
|||||||
Dura-Fan 200-3P4P |
1.0HP / 0.75 KW |
3 Phase |
4 Pole |
1400 RPM |
50 Hz |
800 CMH |
470 CFM |
Dura-Fan 200-3P2P |
2.0HP / 1.5 KW |
3 Phase |
2 Pole |
2800 RPM |
50 Hz |
1100 CMH |
650 CFM |
Dura-Fan 200-1P4P |
1HP / 0.75 KW |
1 Phase |
4 Pole |
1400 RPM |
50 Hz |
800 CMH |
470 CFM |
DURA-FAN SERIES 250 |
|||||||
Dura-Fan 250-3P4P |
2.0HP / 1.5 KW |
3 Phase |
4 Pole |
1400 RPM |
50 Hz |
1600 CMH |
950 CFM |
CLICK HERE FOR COMPLETE DOWN LOADABLE DURA-FAN BROCHURE
Fume extraction systems, for use within the fume hood or fume cupboard in all laboratories, is a critical element of safety and maintaining control of corrosive chemicals and gases. Personnel protection must be maintained at all costs and that is the reason the latest generation of Polypropylene Centrifugal Blowers / Fans have been developed for the laboratory market.
Polypropylene (PP) materials lend themselves to molded configurations that allow for ease of air flow, ease of maintenance, provide excellent ventilating properties while providing a sturdy, compact design with low level sound and high efficiency capabilities. All components of the DURA-FAN blower are made of Molded Polypropylene (PP) and provide excellent protection against corrosive fumes and aggressive exhaust vapors. DURA-FANs may be installed outdoors and are supplied with a suitable cover to shield against the attack of UV radiation. Fans are easily maintained due to their two part molded construction.

DURA-FANs are installed wherever moist, acidic or chemical fumes are present in the fume hood and ducting system. The DURA-FAN eliminates the vapors within the ducting and the fume hood making the laboratory environment safe and productive for future experiments and testing procedures. Blower / fans with varying horse power motors are incorporated within the laboratory in such facilities as K-12 schools, university, hospitals, water treatment plants, pharmaceutical operations, petrochemical facilities and similar applications.
DURA-FAN's are produced of High density (HD) Polypropylene plastics and the base motor is made of galvanized steel. The motor support and mounting attachment stands are also made of high grade steel. The housing is constructed of high density PP in order to provide maximum resistance to corrosion or attack by harsh chemicals. Fiber glass or FRP (fiber glass reinforced plastic) construction is also available upon request. The impellers and casing / housing are to be used in temperatures up to but not exceeding 180 degree F or approx. 80 degree C.
ROTATION
The forward curve centrifugal housing and impellers can be positioned in eight (8) different configurations in 45 degree increments, based on the available spacing and configuration of roof or ceiling mounting locations. Both clockwise and counter clockwise applications may be utilized.
DEPENDABILITY & MAINTENANCE
All DURA-FANs are quality controlled and tested for dependability and wear ability. Their sound and technically advanced construction provides long lasting dependability and proper extraction of chemical fumes and hazardous vapors. Owner or maintenance personnel must undertake annual reviews and inspection check-ups as recommended by supplier to assure the continuous operation of the fans and their components.
WARRANTY
DURA-FANs are warranted for one (1) year from time of purchase and warrant that all Fans / Blowers and their Motors are free of production defects in workmanship and materials used. Proper maintenance must be conducted on all parts within the warranty period and beyond. Warranty will be voided if damage to the impeller, housing etc is caused by improper installation or wiring of all connections.
CLICK HERE FOR COMPLETE DOWN LOADABLE DURA-FAN BROCHURE
![]() |
![]() |
![]() |
![]() |
![]() |
Navigation
Home • Duratop • Duratop Specs • Accessories • Color Chart •Tri-Facial • ResistopSpecs • Chemical Testing • Phenolic Shelving • Liner Boards • Water Faucet Fixtures • Laboratory Sinks • Undercounter Sinks • Lipped Drop-In Sinks • Polypropylene Sinks • Sink Accessories • Peg Boards • Epoxy Peg Boards • Casework & Furniture • Recent Projects • Photo Gallery • Accessories • About us • Contact us
Frequently Asked Questions
What is the extent of epoxy products that Insul-Serv supplies for the scientific and laboratory market?
What variety of laboratory tops does Insul-Serv supply and what are the recommended materials to meet demanding specifications?
How does laboratory casework interact with products offered by Insul-Serv?
Why are there so many varieties of laboratory countertops in the market and which is the best for your particular application?
Are you an international equipment supply company?
Which product is preferred as a pegboard or drying rack, epoxy, phenolic or polypropylene?
What is phenolic resin and how does it differ from epoxy?
What scientific lab furniture does your company supply to the scientific and research industry?
In addition to epoxy resin and phenolic resin, what other laboratory equipment material does Insul-Serv supply?
• Search Engine Optimization by Sequel2 •