Water Saver gas taps - Gas Fixtures - Ball Valve - Needle valve - Deck mount gas valves

Sign Up

WaterSaver Gas Taps

Jump To:Gas-valve
Ball Valve Gas Taps
Needle Value Gas Taps




BALL VALVE Gas / Air / Vacuum

DESCRIPTION
Colored rendering

L-4100-131-WSA
Ball Valve Assembly, Deck Mounted

  1. Mounting: Deck mounted turret base with single outlet.
  2. Non-Removable serrated nozzle.
  3. Valve Body: Forged brass with polished chrome plated finish.
  4. Valve Unit: Quarter-turn open/close with chrome plated brass ball and molded TFE seals.
  5. Handle: Chrome plated forged brass lever handle with color-coded index disc.
  6. Inlet: Furnished with 3/8” IPS mounting shank, (assembled), locknut and washer. 3/8” NPT
    male inlet.
  7. Outlet: Integral (nonremovable) ten serration hose end.
  8. Quality Assurance: Fixture is fully assembled and factory tested prior to shipment.

Additional Models:
L4100-132A-WSA Same as above except with two valves at 90 degrees.
L4100-132S-WSA Same as above except with two valves at 180 degrees.
L4100-134-WSA Same as above except with four valves.

L-4100-131-WSA

DESCRIPTION
Colored rendering

L-4100
Laboratory Ball Valve, Integral Hose End

  1. Application: On/off control of all laboratory gases at pressures up to 75 PSI. When ordered, valve may be specially cleaned, lubricated and packaged for pure gas service.
  2. Valve is certified for gas service by CSA International. Valve is recommended for ADA-compliant applications.Valve Body Forged brass with polished chrome plated finish.
  3. Valve Unit: Quarter-turn open/close with chrome plated brass ball and molded TFE seals.
  4. Handle: Chrome plated forged brass lever handle with color-coded index disc.
  5. Inlet: 3/8” NPT male inlet.
  6. Outlet: Integral (nonremovable) ten serration hose end.
  7. Quality Assurance: Valve is fully assembled and factory tested prior to shipment.
  8. Note: If internal check valve to prevent backflow is required, add suffix “CV”.
L-4100

DESCRIPTION
Colored rendering

L-4200-131-WSA
Ball Valve Assembly, Deck Mounted

  1. Mounting: Deck mounted turret base with single outlet.
  2. Removable Ten Serration hose end.
  3. Valve Body: Forged brass with polished chrome plated finish.
  4. Valve Unit: Quarter-turn open/close with chrome plated brass ball and molded TFE seals.
  5. Handle: Chrome plated forged brass lever handle with color-coded index disc.
  6. Inlet: Furnished with 3/8” IPS mounting shank (assembled), locknut and washer. 3/8” NPT male inlet.
  7. Outlet: 3/8” NPT female outlet with removable ten serration hose end.
  8. Quality Assurance: Fixture is fully assembled and factory tested prior to shipment.

Additional Models:
L4200-132A-WSA Same as above except with two valves at 90 degrees.
L4200-132S-WSA Same as above except with two valves at 180 degrees.
L4200-134-WSA Same as above except with four valves.

L-4200-131-WSA

DESCRIPTION
Colored rendering

L-4200
Laboratory Ball Valve, Removable Hose End, Nylon Handle

  1. Application: On/off control of all laboratory gases at pressures up to 75 PSI. When ordered, valve may be specially cleaned, lubricated and packaged for pure gas service. Valve is certified for gas service by CSA International. Valve is recommended for ADA-compliant applications.
  2. Valve Body: Forged brass with polished chrome plated finish.
  3. Valve Unit: Quarter-turn open/close with chrome plated brass ball and molded TFE seals.
  4. Handle: Chrome plated forged brass lever handle with color-coded index disc.
  5. Inlet: 3/8” NPT male inlet.
  6. Outlet: 3/8” NPT female outlet with removable ten serration hose end.
  7. Quality Assurance: Valve is fully assembled and factory tested prior to shipment.

Additional Models:
L4202 Ball valve with angle serrated hose end.
L4203 Ball valve with quick connect fitting.
L4204 Ball valve with 1/4” OD compression fitting.

Note: If internal backflow check valve is required, add suffix “CV”.

L-4200

RETURN TO TOP

Needle Valve Assemblies - Gas / Air / Vacuum Gas-Taps

DESCRIPTION
Colored rendering

L-2880-131-WSA
Needle Valve Assembly, Deck Mounted

  1. Mounting: Deck mounted turret base with single outlet.
  2. Valve Body: Straight pattern forged brass with polished chrome plated finish.
  3. Valve Unit: Floating stainless steel needle and replaceable stainless steel seat.
  4. Handle: Forged brass four-arm handle with color-coded index disc.
  5. Inlet: Furnished with 3/8” IPS mounting shank (assembled), locknut and washer. 3/8” NPT male inlet.
  6. Outlet: 3/8” NPT female outlet with removable ten serration hose end.
  7. Quality Assurance: Fixture is fully assembled and factory tested prior to shipment.

Additional Models:
L2880-132A-WSA Same as above except with two valves at 90 degrees.
L2880-132S-WSA Same as above except with two valves at 180 degrees.
L2880-134-WSA Same as above except with four valves.

L-2880-131-WSA

DESCRIPTION
Colored rendering

L-2880
Needle Valve, Straight Pattern

  1. Application: Flow regulation of all laboratory gases, including special gases such as nitrogen, oxygen, helium and hydrogen. When ordered, valve may be specially cleaned, lubricated and packaged for pure gas service. Valve is certified for gas service by CSA International.
  2. Valve Body: Straight pattern forged brass with polished chrome plated finish.
  3. Valve Unit: Floating stainless steel needle and replaceable stainless steel seat. Valve goes from closed to open in 3 revolutions of handle, providing good flow regulation.
  4. Handle: Forged brass four-arm handle with color-coded index disc.
  5. Inlet: 3/8” NPT male inlet.
  6. Outlet: 3/8” NPT female outlet with removable ten serration hose end.
  7. Quality Assurance: Valve is fully assembled and factory tested prior to shipment.

Additional Models:
L2882 Needle valve with angle serrated hose end.
L2883 Needle valve with quick connect fitting.
L2884 Needle valve with 1/4” OD compression fitting.

L-2880

DESCRIPTION
Colored rendering

L-2880-141-FT
Double Needle Valve Assembly, Wall Mounted

  1. Mounting: For installation on vertical surfaces (such as drywall) where there is no access behind wall during installation. Wye fitting is threaded onto nipple stubbed out of wall. Threaded escutcheon is then backed up to wall to secure fixture and conceal pipe.
  2. Valve Bodies: Angle pattern forged brass with polished chrome plated finish.
  3. Valve Units: Floating stainless steel needle and replaceable stainless steel seat.
  4. Handles: Forged brass four-arm handles with color-coded index discs.
  5. Inlet: 3/8” NPT female inlet.
  6. Outlets: 3/8” NPT female outlets with removable ten serration hose ends.
  7. Quality Assurance: Fixture is fully assembled and factory tested prior to shipment.
L-2880-141-FT

DESCRIPTION
Colored rendering

L-2880-141-WSA
Double Needle Valve Assembly, Panel/Overhead Carrier Mounted

  1. Mounting: For installation on vertical or horizontal surfaces (such as pipe chases and service carriers) where there is access behind surface during installation. Threaded mounting shank is inserted through hole in surface and secured with locknut and washer.
  2. Valve Bodies: Angle pattern forged brass with polished chrome plated finish.
  3. Valve Units: Floating stainless steel needle and replaceable stainless steel seat.
  4. Handles: Forged brass four-arm handles with color-coded index discs.
  5. Inlet: Furnished with 3/8” IPS mounting shank (assembled), locknut and washer. 3/8” NPT male inlet.
  6. Outlets: 3/8” NPT female outlets with removable ten serration hose ends.
  7. Quality Assurance: Fixture is fully assembled and factory tested prior to shipment.
L-2880-141-WSA

RETURN TO TOP